eAuditor Audits & Inspections

 Checklist

Conducting a thorough mechanical rough-in inspection is essential to ensure that HVAC, plumbing, and electrical systems are installed correctly and meet building codes and standards. Here’s a checklist you can use:

Mechanical Rough-In Inspection

  1. HVAC System:
    • Inspect ductwork for proper installation, including size, routing, and support.
    • Verify that duct joints are sealed properly to prevent air leaks.
    • Check for proper clearance around HVAC equipment and access for servicing.
    • Ensure that HVAC equipment is securely mounted and leveled.
  2. Plumbing System:
    • Inspect water supply lines for proper sizing, material, and support.
    • Verify that water supply lines are properly connected to fixtures and appliances.
    • Check for leaks at joints and connections.
    • Inspect drainage and vent pipes for proper slope, size, and material.
    • Ensure that drainage pipes are properly connected to fixtures and appliances.
    • Verify that plumbing vents terminate above the roofline and are clear of obstructions.
  3. Electrical System:
    • Inspect electrical wiring for proper sizing, type, and routing.
    • Verify that wiring is installed according to electrical code requirements, including proper grounding and bonding.
    • Check for proper installation of electrical boxes, switches, outlets, and fixtures.
    • Ensure that electrical panels are properly labeled and accessible.
    • Verify that wiring is protected from physical damage and installed in conduit where required.
    • Check for proper clearances around electrical equipment and fixtures.
  4. Fire Suppression System (if applicable):
    • Inspect sprinkler pipes and fittings for proper installation and support.
    • Verify that sprinkler heads are installed according to design plans and code requirements.
    • Check for proper clearance around sprinkler heads and obstruction-free coverage.
  5. Gas Piping (if applicable):
    • Inspect gas piping for proper sizing, material, and support.
    • Verify that gas piping is properly connected to appliances and fixtures.
    • Check for leaks at joints and connections using a gas leak detector or soap solution.
  6. Insulation and Firestopping:
    • Inspect insulation around HVAC ducts and pipes for proper installation and coverage.
    • Verify that firestopping materials are installed at penetrations through fire-rated walls and floors.
  7. Accessibility and Clearances:Hou
    • Ensure that mechanical systems are accessible for inspection, maintenance, and repair.
    • Check for proper clearances around mechanical equipment and components.
  8. Documentation and Compliance:
    • Verify compliance with local building codes, regulations, and design plans.
    • Document any deviations from approved plans and address them accordingly.
  9. Safety Precautions:
    • Follow safety protocols and use appropriate personal protective equipment (PPE) during the inspection.
  10. Professional Consultation:
    • Consider involving specialized inspectors or engineers for complex mechanical systems or code compliance issues.

Mechanical Rough-In InspectionBy following this checklist, you can ensure that the mechanical rough-in installation meets regulatory requirements and industry standards, setting the stage for a successful final inspection and completion of the project.

Mechanical Rough-In InspectionTo inspect mechanical rough-in using eAuditor Audits & Inspections checklist, you can follow these steps:

  1. Choose eAuditor Audits & Inspections App:
  2. Create a New Checklist:
    • Use existing checklist or Start a new checklist specifically for mechanical rough-in inspection.
  3. Customize Checklist Items:
    • Create checklist items based on components and aspects you need to inspect. Categories might include HVAC System, Plumbing System, Electrical System, Fire Suppression System (if applicable), Gas Piping (if applicable), Insulation and Firestopping, Accessibility and Clearances, Documentation and Compliance, Safety Precautions, Professional Consultation, etc.
  4. Include Media and Notes Capability:
    • eAuditor Audits & Inspections  allows you to attach photos, videos, and notes to checklist items. This facilitates documenting issues and providing visual evidence.
  5. Use Checkboxes or Rating System:
    • Utilize checkboxes or a rating system (e.g., pass/fail, satisfactory/unsatisfactory) for each inspection item to indicate its status.
  6. Implement Scoring or Grading (Optional):
    • If desired, assign scores or grades to different sections or items to track overall performance or compliance.
  7. Share and Collaborate:
    • Share the checklist with team members or collaborators if you’re working in a team. This enables real-time collaboration and feedback.
  8. Conduct Inspections Using the App:
    • Utilize eAuditor Audits & Inspections during mechanical rough-in inspections to systematically go through each item and record observations. Take photos or videos as needed to document findings.
  9. Review and Generate Reports:
    • After completing the inspection, review the checklist and any attached media to ensure thoroughness. eAuditor Audits & Inspections allows you to generate reports or summaries for sharing with clients or stakeholders.
  10. Follow Up and Take Action:
    • Based on the inspection findings, prioritize any necessary corrective actions or follow-ups. Use the checklist as a reference for addressing identified issues.

By utilizing eAuditor Audits & Inspections checklist for mechanical rough-in inspections, you can enhance efficiency, accuracy, and documentation of the inspection process.


Leave a Reply

Your email address will not be published. Required fields are marked *

This is a staging enviroment